Technical FAQs

Ask a Question

Are auxiliary contacts available for the 8911 definite purpose starters?

Issue:
Are auxiliary contacts available for the 8911 definite purpose starters?

Product Line:
Definate Purpose starters and contactors

Environment:
8910DPA and 8911DPS

Cause:
Additional accessories required for the application

Resolution:
Auxiliary contacts are available for the 8911DPS type devices, select from the chart listed below:

Maximum of two modules per contactor, one module per side:

 
Contact arrangement 20-90 amp 
series B and series C after date code 1401
20-40A 
series C before date code 1401
1 N.O. 9999D10 9999DD10
1 N.C. 9999D01 9999DD01
1 N.O./1 N.C. 9999D11 9999DD11
2 N.O.  9999D20 9999DD20

This also applies to the 8910DPA contactors

The 8911DS compact units will not accept auxiliary contacts, other means of holding circuit must be supplied or maintained control contacts must be used.



CTA-ID : 2003117
Was this helpful?
What can we do to improve the information ?